Tuotteen kuvaus
An implanttien momenttiavain is a reusable tool used in the installation process of dental implants, consisting of a wrench body and a wrench The rod is composed of stainless steel and titanium alloy materials. Used during the dental implantation process. Passive products. wrong Aseptic provision. Before use, the organization shall provide instructions Sterilize with instructions. Screwed up, consisting of a rotating cap and screws, made of stainless steel and aluminum alloy materials. stay Used during the dental implantation process. Passive products. Non sterile provision. Before use, the user organization should follow the instructions to proceed with Sterilize. (Model)
HYG-DH03,HYG-DH04,HYG01-195,HYG-D11173,HYG-DH174
Käyttötarkoitus
Implantin asettamisen jälkeen, tukipilarien ja kruunujen asennus, jäljennösten ottaminen jne.
Käyttöalue
Se soveltuu käytettäväksi hammasimplanttikirurgiassa ja sen restauroinnissa sekä hammaskruunujen valmistuksessa.
Käyttö
Kun kiristät jakoavaimella, työnnä vastaava ruuvimeisseli (tai komponentti) jakoavaimen reikään pystysuoraan. Kun kuulet naksahduksen oikean asennuksen varmistamiseksi, Kuten alla on esitetty:

- Varmista, että nuoli osoittaa myötäpäivään, ja kiristä korjauskokoonpano kyseisen tuotteen käyttöohjeessa määritellyllä vääntömomentilla. Käytä tarvittaessa korjausasennelman irrottamiseen jakoavainta niin, että suuntavilkku on peruutustilassa. Toimintatapa kuten alla on esitetty laiha: a, b ja c. Kuva c on peruutustila.
- Kierrä korjauskokoonpano irti painamalla käsin vipuvarsi c:tä.

Varotoimenpiteet ja varoitukset
- Hammasimplanttityökalut on puhdistettava ja steriloitava ennen käyttöä.
- Hammasimplanttien työkalujen uudelleenkäsittelyssä käytettävät kemialliset reagenssit eivät saa olla voimakkaita happoja, jotka syövyttävät voimakkaasti, tai voimakkaita emäksisiä liuoksia.
- Kun hammasimplanttityökalut ovat vaurioituneet tai kuluneet merkittävästi, ne on vaihdettava uusiin.
Sterilointimenetelmä
- Nosta momenttiavain ja kierrä sterilointia varten ehjään sterilointipussiin.
- Suorita sterilointi korkeassa lämpötilassa ja korkeassa paineessa 136 °C ± 2 °C:n lämpötilassa. Tai aseta paikallisten määräysten mukaisesti.
- Steriloinnin jälkeen poista työkärki sterilointilaitteesta ja suorita luonnollinen kuivaus. On varmistettava, että se on täysin kuiva.
Varastointimenetelmä
Tieteellisten implanttien istutustyökalut on säilytettävä puhtaassa, kuivassa ja tuuletetussa ympäristössä, jonka suhteellinen kosteus on 10% - 93% ja sisälämpötila ilman syövyttäviä kaasuja -20C -*55C.
Voimassaoloaika
5 vuotta.
Kohderyhmä
Aikuisten ja lasten hammaslääkäripotilaat.
TEKNISET TIEDOT
HYG-DH03-11(25mm), HYG-DH03-12(25mm), HYG-DH03-L3(25mm), HYG-DH03-14(25mm), HYG-DH03-15(25mm), HYG-DH03-L6(25mm), HYG-DH03-L7(25mm), HYG-DH03-L8(25mm), HYG-DH03-51 (20mm), HYG-DH03-52(20mm), HYG-DH03-53(20mm), HYG-DH03-54(20mm), HYG-DH03-55(20mm), HYG-DH03-56(20mm), HYG-DH03-57(20mm), HYG-DH03-58(20mm), HYG-DH04-L1(25mm), HYG-DH04-12(25mm), HYG-DH04-13(25mm), HYG-DH04-14(25mm), HYG-DH04-15(25mm), HYG-DH04-16(25mm), HYG-DH04-1.7(25mm), HYG-DH04-18(25mm), HYG-DH04-51(20mm), HYG-DH04-52(20mm), HYG-DHO4S3(20mm), HYG-DH04-54(20mm), HYG-DH04-55(20mm), HYG-DH04-56(20mm), HYG-DH04-57(20mm), HYG-DH04-58(20mm), HYG-DH83, HYG-DH84, HYG-DH85,HYG-DH86,HYG-DH87, HYG-DH88, HYG-DH89, HYG-DH90, HYG-DH173-11(25mm), HYG-DH173-1_2(25mm), HYG-DH173-L3(25mm), HYG-DH173-14(25mm), HYG-DH173-15(25mm), HYG-DH173-L6(25mm), HYG-DH173-17(25mm), HYG-DH173-L8(25mm), HYG-DH173-51(20m m), HYG-DH173-52(20mm), HYG-DH173-53(20mm), HYG-DH173-54(20mm), HYG-DH173-55(20mm), HYG-DH173-56(20mm), HYG-DH173-57(20mm), HYG-DH173-58(20mm), HYG-DH174-11(25mm), HYG-DH174-12(25mm), HYG-DH174-L3(25mm). HYG-DH174-14(25mm), HYG-DH174-L5(25mm), HYG-DH174-L6(25mm), HYG-DH174-$1(20mm), HYG-DH174-52(20mm), HYG-DH174-53(20mm), HYG-DH174-54(20mm), HYG-DH174-55(20mm), HYG-DH174-56(20mm).
Sovellettavat mallit
Malli |
Sovellettava tuotemerkki |
Hex0.9 | Xive |
Hex1.0 | Ankylos |
Hex1.2 | Osstem | DIO | 3I | C-Tech | ICM | Megagen | T-plus | T-plus |
Hex1.25 | Cortex | Ticare | ABT | Zimmer |
Hex1.27 | Dentium | Dentis | Bego | Astra | Adin | MIS | MIS | Alpha | Biotec | Biohorizon |
Hex1.4 | ICX |
NOB | Nobel | Basic | Omni-Tight | Dental master |
ITI | Straumann | Trausim | Bioconcept |
Soveltamisala
Käytetään hammasimplanttiprosesseissa.
Ohjeet
Valitse sopiva ruuvi ja kiinnitä se momenttiavaimella.
Varotoimenpiteet ja varoitukset
- Hammasimplantti työkalut on puhdistettava ja steriloitava ennen käyttöä.
- Hammasimplanttien työkalujen uudelleenkäsittelyssä käytettävät kemialliset reagenssit eivät saa olla voimakkaita happoja, jotka syövyttävät voimakkaasti, tai voimakkaita emäksisiä liuoksia.
- Kun hammasimplanttityökalut ovat vaurioituneet tai kuluneet merkittävästi, ne on vaihdettava uusiin.