Instrukcja obsługi zestawu Universal Implant Driver Kit.
Opis produktu
An klucz dynamometryczny do implantów is a reusable tool used in the installation process of dental implants, consisting of a wrench body and a wrench The rod is composed of stainless steel and titanium alloy materials. Used during the dental implantation process. Passive products. wrong Aseptic provision. Before use, the organization shall provide instructions Sterilize with instructions. Screwed up, consisting of a rotating cap and screws, made of stainless steel and aluminum alloy materials. stay Used during the dental implantation process. Passive products. Non sterile provision. Before use, the user organization should follow the instructions to proceed with Sterilize. (Model)
HYG-DH03,HYG-DH04,HYG01-195,HYG-D11173,HYG-DH174
Przeznaczenie
Po wszczepieniu implantów, montażu łączników, koron, pobraniu wycisków itp.
Zakres zastosowania
Nadaje się do stosowania w chirurgii implantologicznej i jej odbudowie oraz podczas przygotowywania koron dentystycznych przez techników.
Użycie
Podczas dokręcania kluczem należy włożyć odpowiedni śrubokręt (lub element) do otworu klucza pionowo. Po usłyszeniu kliknięcia oznaczającego prawidłową instalację, jak pokazano poniżej:

- Upewnić się, że strzałka jest skierowana zgodnie z ruchem wskazówek zegara, a następnie dokręcić zespół naprawczy momentem podanym w "Instrukcji obsługi" danego produktu. W razie potrzeby należy użyć klucza do odkręcenia zespołu naprawczego, tak aby wskaźnik kierunku znajdował się w trybie odwrotnym. Metoda działania przedstawiona poniżej: a, b i c. Rysunek c przedstawia tryb odwrotny.
- Ręcznie nacisnąć ramię dźwigni c, aby odkręcić zespół naprawczy.

Środki ostrożności i ostrzeżenia
- Narzędzia do implantów dentystycznych muszą być czyszczone i sterylizowane przed użyciem.
- Odczynniki chemiczne stosowane do regeneracji narzędzi do implantów dentystycznych nie powinny być silnymi kwasami o silnym działaniu korozyjnym ani silnymi roztworami alkalicznymi.
- Gdy narzędzia do implantów dentystycznych są uszkodzone lub znacznie zużyte, należy je wymienić na nowe.
Metoda sterylizacji
- Podnieść klucz dynamometryczny i wkręcić do nieuszkodzonego worka sterylizacyjnego w celu sterylizacji.
- Przeprowadzić sterylizację wysokotemperaturową i wysokociśnieniową w temperaturze 136 °C± 2 °C. Lub ustawić zgodnie z lokalnymi przepisami.
- Po sterylizacji wyjąć końcówkę roboczą ze sterylizatora i przeprowadzić naturalne suszenie. Należy upewnić się, że jest całkowicie sucha.
Metoda przechowywania
Narzędzia do sadzenia implantów naukowych powinny być przechowywane w czystym, suchym, wentylowanym środowisku o wilgotności względnej od 10% do 93% i temperaturze wewnętrznej bez gazów korozyjnych w zakresie od -20C do*55C.
Okres ważności
5 lat.
Docelowi odbiorcy
Dorośli i dziecięcy pacjenci stomatologiczni.
SPECYFIKACJA
HYG-DH03-11(25mm), HYG-DH03-12(25mm), HYG-DH03-L3(25mm), HYG-DH03-14(25mm), HYG-DH03-15(25mm), HYG-DH03-L6(25mm), HYG-DH03-L7(25mm), HYG-DH03-L8(25mm), HYG-DH03-51 (20mm), HYG-DH03-52(20mm), HYG-DH03-53(20mm), HYG-DH03-54(20mm), HYG-DH03-55(20mm), HYG-DH03-56(20mm), HYG-DH03-57(20mm), HYG-DH03-58(20mm), HYG-DH04-L1(25mm), HYG-DH04-12(25mm), HYG-DH04-13(25mm), HYG-DH04-14(25mm), HYG-DH04-15(25mm), HYG-DH04-16(25mm), HYG-DH04-1.7(25mm), HYG-DH04-18(25mm), HYG-DH04-51(20mm), HYG-DH04-52(20mm), HYG-DHO4S3(20mm), HYG-DH04-54(20mm), HYG-DH04-55(20mm), HYG-DH04-56(20mm), HYG-DH04-57(20mm), HYG-DH04-58(20mm), HYG-DH83, HYG-DH84, HYG-DH85, HYG-DH86, HYG-DH87, HYG-DH88, HYG-DH89, HYG-DH90, HYG-DH173-11(25mm), HYG-DH173-1_2(25mm), HYG-DH173-L3(25mm), HYG-DH173-14(25mm), HYG-DH173-15(25mm), HYG-DH173-L6(25mm), HYG-DH173-17(25mm), HYG-DH173-L8(25mm), HYG-DH173-51(20mm), HYG-DH173-52(20mm), HYG-DH173-53(20mm), HYG-DH173-54(20mm), HYG-DH173-55(20mm), HYG-DH173-56(20mm), HYG-DH173-57(20mm), HYG-DH173-58(20mm), HYG-DH174-11(25mm), HYG-DH174-12(25mm), HYG-DH174-L3(25mm). HYG-DH174-14(25mm), HYG-DH174-L5(25mm), HYG-DH174-L6(25mm), HYG-DH174-$1(20mm), HYG-DH174-52(20mm), HYG-DH174-53(20mm), HYG-DH174-54(20mm), HYG-DH174-55(20mm), HYG-DH174-56(20mm).
Odpowiednie modele
Model |
Odpowiednia marka |
Hex0.9 | Xive |
Hex1.0 | Ankylos |
Hex1.2 | Osstem | DIO | 3I | C-Tech | ICM | Megagen | T-plus |
Hex1.25 | Cortex | Ticare | ABT | Zimmer |
Hex1.27 | Dentium | Dentis | Bego | Astra | Adin | MIS | Alpha | Biotec | Biohorizon |
Hex1.4 | ICX |
NOB | Nobel | Basic | Omni-Tight | Dental Master |
ITI | Straumann | Trausim | Bioconcept |
Zakres zastosowania
Używany w procesach związanych z implantami dentystycznymi.
Instrukcje
Wybierz odpowiednią śrubę i zabezpiecz ją kluczem dynamometrycznym.
Środki ostrożności i ostrzeżenia
- Implant dentystyczny narzędzia muszą być czyszczone i sterylizowane przed użyciem.
- Odczynniki chemiczne stosowane do regeneracji narzędzi do implantów dentystycznych nie powinny być silnymi kwasami o silnym działaniu korozyjnym ani silnymi roztworami alkalicznymi.
- Gdy narzędzia do implantów dentystycznych są uszkodzone lub znacznie zużyte, należy je wymienić na nowe.