//Handpiece Turbine Cleaner

Handpiece Turbine Cleaner

219,00

Category:

Description

Handpiece Turbine Cleaner

Tool for cleaning out blocked and obstructed handpiece water lines
Removes water line blockages caused by inert biofilm and microparticles carried in the water supply
Prevents initial residue and particle build-up when used regularly with warm water
Easy to use

Handpiece Turbine Cleaner

Handpiece Turbine Cleaner ® is a unique tool for cleaning blockages in the turbine and quick coupling through the use of a helical pushing movement of an injector piston.

Handpiece Turbine Cleaner ® serves two purposes:

  1. Removal of blockages caused by micro particles carried in the water supply and inert biofilm residue left in the turbine.
  2. Prevention of initial residue/particle build ups by using the smart cleaner with hot water at two days intervals

Blockage Removal In The Turbine

(a) Fit the connector of the Handpiece Turbine Cleaner to the turbine/quick coupling.
(b) Undo Handpiece Turbine Cleaner  threaded handle.
(c) Remove Handpiece Turbine Cleaner piston.
(d) Half-fill Handpiece Turbine Cleaner with hot water.
(e) Return piston toHandpiece Turbine Cleaner, push it inside with normal hand pressure.
(f) If not successful or resistance is too great for normal hand pressure, fit the threaded handle and screw it down to stop.

Smart Cleaner that fits to Midwest Standard Turbines


Smart Cleaner that fits to Borden Standard Turbines

Adaptor for contra angle handpiece (E type)

Adaptor for dental unit tube

General Instructions For Smart Cupper®

Smart Cupper® is necessary when, in a multi hole turbine, only one hole is blocked.

  1. Take the bore cup off the case and connect it to the turbine.
  2. Adjust the hole of the bore cup exactly above the blocked hole in the turbine.
  3. Connect the turbine with the case clump and close the screw.
  4. Connect the turbine to the Smart Cleaner® and run a routine cleaning.

General Instructions For Smart Connect®

Smart Connect® is necessary for contra angle handpieces (E Type).

  1. Connect the Smart Cleaner® to the Smart Connect®
  2. Connect the contra angle handpiece to the Smart Connect®
  3. Run a routine use – as shown in Smart Cleaner® instructions

General Instructions For Smart Tube®

Smart Tube® is necessary when the turbine tube in the dental unit is blocked.

  1. Disconnect the tube from the dental unit.
  2. Connect the pin side of the Smart Tube® to the dental unit tube.
  3. Connect the other side of the Smart Tube® to the Smart Cleaner®
  4. Run a routine use – as shown in Smart Cleaner® instructions

Reviews

There are no reviews yet.

Be the first to review “Handpiece Turbine Cleaner”

Your email address will not be published. Required fields are marked *

×
Hello, If you can't find something just send me message!

Privacy Preference Center

Close your account?

Your account will be closed and all data will be permanently deleted and cannot be recovered. Are you sure?