Universal Implant Driver Kit Instructions.
Descrição do produto
Um chave dinamométrica para implantes is a reusable tool used in the installation process of dental implants, consisting of a wrench body and a wrench. The rod is composed of stainless steel and titanium alloy materials. Used during the dental implantation process. Passive products. Wrong aseptic provision. Before use, the organization shall provide instructions for sterilization. Screwed up, consisting of a rotating cap and screws, made of stainless steel and aluminum alloy materials. Stay used during the dental implantation process. Passive products. Non sterile provision. Before use, the user organization should follow the instructions to proceed with Sterilization. (Model)
HYG-DH03, HYG-DH04, HYG01-195, HYG-D11173,HYG-DH174
Utilização prevista
Após a colocação de implantes, instalação de pilares, coroas, moldagem, etc.
Âmbito de utilização
É adequado para utilização em cirurgia de implantes dentários e sua restauração e durante a preparação de coroas dentárias por técnicos.
Utilização
When tightening with the wrench, please insert the corresponding screwdriver (or component) into the wrench hole vertically. After you hear a click for proper installation, as shown below:
- Make sure the arrow points clockwise, and use the torque specified in the “Instruction Manual” of the relevant product to tighten the repair the assembly. If necessary, use a wrench to exit the repair assembly so that the direction indicator is in reverse mode. Operation method as shown lean, below: a, b, and c. Figure C is the reverse mode.
- Manually apply pressure to the lever arm C to unscrew the repair assembly.
Precauções e avisos
- Os instrumentos para implantes dentários devem ser limpos e esterilizados antes de serem utilizados.
- The chemical reagents used for the reprocessing of dental implant tools should not be strong acids with strong corrosiveness or strong alkaline solutions.
- Quando as ferramentas de implantes dentários estão danificadas ou muito gastas, devem ser substituídas por novas.
Método de esterilização
- Levantar a chave dinamométrica e aparafusar num saco de esterilização não danificado para esterilização.
- Perform high-temperature and high-pressure sterilization at a temperature of 136 °C±2 °C. Or set according to local regulations.
- Após a esterilização, retirar a ponta de trabalho do esterilizador e efetuar a secagem natural. Deve assegurar-se de que está completamente seca.
Método de armazenamento
As ferramentas de plantação para implantes científicos devem ser armazenadas num ambiente limpo, seco e ventilado, com uma humidade relativa de 10% a 93% e uma temperatura interior sem gases corrosivos entre -20C e *55C.
Período de validade
5 anos.
Público-alvo
Pacientes dentários adultos e pediátricos.
ESPECIFICAÇÕES
HYG-DH03-11(25mm), HYG-DH03-12(25mm), HYG-DH03-L3(25mm), HYG-DH03-14(25mm), HYG-DH03-15(25mm), HYG-DH03-L6(25mm), HYG-DH03-L7(25mm), HYG-DH03-L8(25mm), HYG-DH03-51 (20mm), HYG-DH03-52(20mm), HYG-DH03-53(20mm), HYG-DH03-54(20mm), HYG-DH03-55(20mm), HYG-DH03-56(20mm), HYG-DH03-57(20mm), HYG-DH03-58(20mm), HYG-DH04-L1(25mm), HYG-DH04-12(25mm), HYG-DH04-13(25mm), HYG-DH04-14(25mm), HYG-DH04-15(25mm), HYG-DH04-16(25mm), HYG-DH04-1.7(25mm), HYG-DH04-18(25mm), HYG-DH04-51(20mm), HYG-DH04-52(20mm), HYG-DHO4S3(20mm), HYG-DH04-54(20mm), HYG-DH04-55(20mm), HYG-DH04-56(20mm), HYG-DH04-57(20mm), HYG-DH04-58(20mm), HYG-DH83, HYG-DH84, HYG-DH85,HYG-DH86,HYG-DH87, HYG-DH88, HYG-DH89, HYG-DH90, HYG-DH173-11(25mm), HYG-DH173-1_2(25mm), HYG-DH173-L3(25mm), HYG-DH173-14(25mm), HYG-DH173-15(25mm), HYG-DH173-L6(25mm), HYG-DH173-17(25mm), HYG-DH173-L8(25mm), HYG-DH173-51(20m m), HYG-DH173-52(20mm),HYG-DH173-53(20mm), HYG-DH173-54(20mm), HYG-DH173-55(20mm), HYG-DH173-56(20mm), HYG-DH173-57(20mm), HYG-DH173-58(20mm), HYG-DH174-11(25mm), HYG-DH174-12(25mm), HYG-DH174-L3(25mm). HYG-DH174-14(25mm), HYG-DH174-L5(25mm), HYG-DH174-L6(25mm), HYG-DH174-$1(20mm), HYG-DH174-52(20mm), HYG-DH174-53(20mm), HYG-DH174-54(20mm), HYG-DH174-55(20mm), HYG-DH174-56(20mm)
Modelos aplicáveis
Modelo |
Marca aplicável |
Hex0.9 | Xive |
Hex1.0 | Anquilos |
Hex1.2 | Osstem | DIO | 3I | C-Tech | ICM | Megagen | T-plus |
Hex1.25 | Cortex | Ticare | ABT | Zimmer |
Hex1.27 | Dentium | Dentis Bego | Astra | Adin | MIS | Alfa | Biotec | Biohorizonte |
Hex1.4 | ICX |
NOB | Nobel | Basic | Omni-Tight | Dental master |
ITI | Straumann | Trausim | Bioconcept |
Âmbito de aplicação
Utilizado para processos de implantes dentários.
Instruções
Escolha um parafuso adequado e fixe-o com uma chave dinamométrica.
Precauções e avisos
- Implante dentário as ferramentas devem ser limpas e esterilizadas antes de serem utilizadas.
- The chemical reagents used for the reprocessing of dental implant tools should not be strong acids with strong corrosiveness or strong alkaline solutions.
- Quando as ferramentas de implantes dentários estão danificadas ou muito gastas, devem ser substituídas por novas.
Buy the Best Uiversal Implant here